A goniometric light gets its intensity distribution function (how much light goes in any one direction) from one of two sources: (i) an industry-standard file, (ii) from distribution data passed directly via the IfcLightIntensityDistribution.
The light distribution provides the luminous intensity distribution according to some standardized light distribution curves.
SELECT
| Type | Definition | 
| IfcExternalReference | Light distribution is represented by a standard photometric data file such as Eulumdat, IES, CIBSE TM14. | 
| IfcLightIntensityDistribution | For representing a light distribution directly the following values needs to be given in a table like structure with column and row headings. These headings should contain the angles (C/γ or B/β ) and the table body contains the intensity values, (normally normalized to cd/Klm). The angles can be non- equidistant and the angle steps can be almost any value in the valid range, so a list of all available angles in both directions covers all cases. | 
HISTORY New type in IFC2x2.
| Type | Description | 
|---|---|
| IfcExternalReference | |
| IfcLightIntensityDistribution | 
 <xs:group name="IfcLightDistributionDataSourceSelect">
  <xs:choice>
   <xs:element ref="ifc:IfcExternalReference"/>
   <xs:element ref="ifc:IfcLightIntensityDistribution"/>
  </xs:choice>
 </xs:group>
TYPE IfcLightDistributionDataSourceSelect = SELECT (
 IfcExternalReference, 
 IfcLightIntensityDistribution);
END_TYPE;
  References: IfcLightSourceGoniometric